OMRON Z-15GQ21-B

Actuator Panel mount cross roller plunger (12.7 x 4.8 dia., Stainless steel roller)
Contact form SPDT
Contact gap 0.5 mm
Terminal Screw terminal (M4)
Load General load
Rated current 15 A
Ratings (AC) Non-Inductive load Rated voltage: 125 VAC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 250 VAC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 2.5 A(NC) 1.25 A(NO)
Rated voltage: 500 VAC / Resistive load: 10 A(NC) 10 A(NO) / Lamp load: 1.5 A(NC) 0.75 A(NO)
Ratings (AC) Inductive load Rated voltage: 125 VAC / Inductive load: 15 A(NC) 15 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 250 VAC / Inductive load: 15 A(NC) 15 A(NO) / Motor load: 3 A(NC) 1.5 A(NO)
Rated voltage: 500 VAC / Inductive load: 6 A(NC) 6 A(NO) / Motor load: 1.5 A(NC) 0.75 A(NO)
Ratings (DC) Non-Inductive load Rated voltage: 8 VDC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 14 VDC / Resistive load: 15 A(NC) 15 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 30 VDC / Resistive load: 6 A(NC) 6 A(NO) / Lamp load: 3 A(NC) 1.5 A(NO)
Rated voltage: 125 VDC / Resistive load: 0.5 A(NC) 0.5 A(NO) / Lamp load: 0.5 A(NC) 0.5 A(NO)
Rated voltage: 250 VDC / Resistive load: 0.25 A(NC) 0.25 A(NO) / Lamp load: 0.25 A(NC) 0.25 A(NO)
Ratings (DC) Inductive load Rated voltage: 8 VDC / Inductive load: 15 A(NC) 15 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 14 VDC / Inductive load: 10 A(NC) 10 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 30 VDC / Inductive load: 5 A(NC) 5 A(NO) / Motor load: 5 A(NC) 2.5 A(NO)
Rated voltage: 125 VDC / Inductive load: 0.05 A(NC) 0.05 A(NO) / Motor load: 0.05 A(NC) 0.05 A(NO)
Rated voltage: 250 VDC / Inductive load: 0.03 A(NC) 0.03 A(NO) / Motor load: 0.03 A(NC) 0.03 A(NO)
Inrush current NC: 30 A
NO: 15 A
Ambient temperature Operating : -25 to 80 ℃
(with no icing or condensation)
Ambient humidity Operating: 35 to 85% RH
 
Speed of permissible operation 0.01 mm/s to 1 m/s
Permissible operating frequency (Mechanically) 240 operations / 1 minute max.
Permissible operating frequency (Electrically) 20 operations / 1 minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength Between each terminal of the same polarities: 1000 VAC 50/60 Hz for 1 min
Between live-metallic part and ground: 2000 VAC 50/60 Hz for 1 min
Between each terminal and non-live-metallic part: 2000 VAC 50/60 Hz for 1 min
Mechanical durability 20,000,000 operations min.
Electrical durability 500,000 operations min.
Degree of protection IP00
Degree of protection against electric shock Class I
Proof tracking index(PTI) 175

XEM CATALOG SẢN PHẨM TẠI ĐÂY

Sản phẩm cùng loại
Zalo
Hotline