OMRON A165E-S-01
Type | Emergency Stop Switch | |||
---|---|---|---|---|
Non-lighted A165E-S/A165E-M |
Lighted A165E-LS/A165-LM |
Non-lighted, One-piece construction A165E-U |
||
Allowable operating frequency |
Mechanical | 20 operations/minute max. | ||
Electrical | 10 operations/minute max. | |||
Insulation resistance | 100 MΩ min. (at 500 VDC) | |||
Dielectric strength |
Between terminals of same polarity |
1,000 VAC, 50/60 Hz for 1 min | ||
Between terminals of different polarity |
2,000 VAC 50/60 Hz for 1 min | |||
Between each terminal and ground |
2,000 VAC 50/60 Hz for 1 min | |||
Between lamp terminals |
1,000 VAC, 50/60 Hz for 1 min *1 | — | ||
Vibration resistance |
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) | ||
Shock resistance |
Destruction | 500 m/s2 | ||
Malfunction | 300 m/s2 max. (malfunction within 1 ms) |
150 m/s2 max. (malfunction within 1 ms) |
||
Durability | Mechanical | 100,000 operations min. | ||
Electrical | 100,000 operations min. | |||
Degree of protection | IP65 Oil-resistant *2 | IP65 *2 | IP65 Oil-resistant *2 | |
Electric shock protection class | Class II | |||
PTI (tracking characteristic) | 175 | |||
Degree of contamination | 3 (EN60947-5-1) | |||
Weight | Approx. 16 g (in case of 2NC(2) Switches) | |||
Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |||
Ambient operating humidity | 35% to 85% | |||
Ambient storage temperature | -25 to 65°C (with no icing or condensation) |